Robe ROBIN Pointe Especificaciones

Busca en linea o descarga Especificaciones para Reflectores Robe ROBIN Pointe. Robe ROBIN Pointe Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 2 - Robin Pointe

103.4 Replacing rotating gobos DANGER!Replace gobos with the device switched off only.Unplug from mains before!1. Disconnect the xture from mains and

Pagina 3 - 1. Safety instructions

113.5 Rigging the xtureA structure intended for installation of the xture (s) must safely hold weight of the xture(s) placed on it. The structure

Pagina 4

12Truss installation1.Bolt each clamp (1) to the omega holder (3) with M12 bolt and lock nut through the hole in the holder.2.Fasten the omega holder

Pagina 5 - 2. Fixture exterior view

133.6 DMX-512 connectionThe xture is equipped with both 3-pin and 5-pin XLR sockets for DMX input and output.The sockets are wired in parallel.Only

Pagina 6 - 3.1 Connection to the mains

143.7 Ethernet connectionThe xtures on a data link are connected to the Ethernet with ArtNet communication protocol.The control soft-ware running on

Pagina 7 - 3.2 Changing the lamp

15Ethernet / DMX operationOption “ Artnet" (gMaI or gMA2 or sACN) has to be selected from “Ethernet Mode” menu at rst xture.Option “Ethernet To

Pagina 8 - 3.3 Lamp adjustment

163.8 Wireless DMX operationThe wireless version of the Robin Pointe is equipped with the Lumen Radio CRMX module and antenna for receiving DMX sign

Pagina 9

174. Remotely controllable functionsLampThe Robin Pointe is to be operated with a Osram Sirius HRI 280W RO lamp. The Osram Sirius HRI 280W RO is a la

Pagina 10 - 3.4 Replacing rotating gobos

185. Control menu mapDefault settings=Bold printTab Level 1 Level 2 Level 3 Level 4 Level 5 Level 6Addressing Settings DMX Address 001-255 Ether

Pagina 11 - 3.5 Rigging the xture

19Tab Level 1 Level 2 Level 3 Level 4 Level 5 Level 6Lamp OffFixture PositionFixture Temperatures Head TemperatureAmbient TemperatureBase Temperatures

Pagina 12 - DANGER TO LIFE!

2Table of contents1. Safety instructions ... 32.

Pagina 13 - 3.6 DMX-512 connection

20Tab Level 1 Level 2 Level 3 Level 4 Level 5 Level 6Focus Rot. Gobos 0-255Play Dynamic DemoPlay Static DemoMusicTrigger Off, OnPreset Playback NoneTe

Pagina 14 - 3.7 Ethernet connection

216. Control menu The Robin Pointe is equipped with the QVGA Robe touch screen with battery backup which allows to set the xture´s behaviour accord

Pagina 15 - Ω resistor

22Note: The green icon at the top right corner of the screen indicates the level of the display battery charging. If the whole icon is green, the batt

Pagina 16 - 3.8 Wireless DMX operation

23 address.The IP uniquely identies any node (xture) on a network. There cannot be 2 xtures with the same IP address on the network! Defaul

Pagina 17

24 been fabricated. Maximum Res. - A maximum temperature of the xture head since the counter was last reset. In order to reset this coun

Pagina 18 - 5. Control menu map

25 Fixture Temperatures - Recorded temperatures which have exceeded dened levels.Note: The log buffer can contain 8000 records max. If the buffer i

Pagina 19 - Optics/Prism/Frost Res

26 igoes goes from position to position. Gobo Wheel Moving - The menu item enables to close light output while the rot. gobo wheel goes f

Pagina 20

27 Play Dynamic Demo - This option uses all Robin Pointe functions including pan/tilt movement and therefore is good for a complete introduction

Pagina 21 - 6. Control menu

286.6 Tab "Service"Adjust DMX Values - The menu allows you to set all effects to desired positions before ne calibration of the effects .Ca

Pagina 22 - 6.1 Tab " Address"

29 After having calibrated all effects, touch the [conrm] to save adjusted values and reset the xture. Load Default Calibrations - The item loads

Pagina 23

3FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START - UPThis device has left our premises in absolutely perfect cond

Pagina 24

30 command. If the lamp is started directly from the control panel, the time delay will be ignored. Lamp Light Sensor - Select this item to switch

Pagina 25

311...Another options for this command (only for Robe´s xtures): value PARAMETER_DATA=0x84 - lamp OFF by DMX value on DMX channel value PAR

Pagina 26

32position.Prism 2 Rotation Error 1 (Prism 2 Rotation Error 2 )The messages will appear after the reset of the circular prism wheel if this effect is

Pagina 27

339. Technical SpecicationsElectrical Power supply:...electronic auto-ranging Input voltage range:... supply

Pagina 28 - 6.6 Tab "Service"

34Control Graphic touch screen for xture setting and addressing Gravitation sensor for auto screen positioning Battery backup of the touch s

Pagina 29

35Dimensions (mm)Accessories Omega holder (No.99010420)...2 pcs10. Maintenance and cleaningIt is absolutely essential

Pagina 30

36The front objective lens will require weekly cleaning as smoke-uid tends to building up residues, reducing the light-output very quickly. The coo

Pagina 31

3712. Photometric diagramsAll diagrams are for full power of the lamp (Standard Mode)

Pagina 34

4If the xture has been exposed to drastic temperature uctuation (e.g. after transportation), do not switch it on immediately. The arising condensati

Pagina 36 - 11. ChangeLog

DMX protocol1 2 31 1 1Pan0 - 255 Pan movement by 540°proportional2 * 2Pan Fine0 - 255 Fine control of pan movementproportional3 2 3Tilt0 - 255 Tilt mo

Pagina 37 - 12. Photometric diagrams

DMX protocol1 2 3Mode/channelDMX ValueFunctionType of control230 - 239Lamp Offstep240 - 255Reserved7 5 7Colour wheel Continual positioning0 Open/white

Pagina 38

DMX protocol1 2 3Mode/channelDMX ValueFunctionType of control1 - 255 Time of colour wheel movement (0.1 sec. --- >25.5 sec.)proportional* * 12Stati

Pagina 39

DMX protocol1 2 3Mode/channelDMX ValueFunctionType of control244 - 249 Random gobo selection by audio controlstep(Set microphone sensitivity in menu

Pagina 40

DMX protocol1 2 3Mode/channelDMX ValueFunctionType of control200 - 201 Open/hole step202 - 221 Forwards gobo wheel rotation from fast to slowproport

Pagina 41

DMX protocol1 2 3Mode/channelDMX ValueFunctionType of control1 - 179 Frost from 0% to 100%proportional180 - 189 100% froststep190 - 211 Pulse closing

Pagina 42

DMX protocol1 2 3Mode/channelDMX ValueFunctionType of control0 - 255 Fine dimmingproportionalPage 7

Pagina 44 - Rotating gobo wheel

52. Fixture exterior view Rear panel of the base:1 - Ethernet input-RJ452 - Power 3 - 3-pin DMX Out 4 - 5-pin DMX Out 5 - Fuse holder-live 6 - Fu

Pagina 45

63. Installation Fixtures must be installed by a qualied electrician in accordance with all national and local electrical and const

Pagina 46

73.2 Changing the lamp DANGER ! Install the lamp with the xture unplug from mains !To insert the new lamp.1. Disconnect the xture from mains and a

Pagina 47

83.3 Lamp adjustment The lamp holder is aligned at the factory. Due to differences between lamps,the ne adjustment may improve light performance.For