Robe ROBIN Pointe Especificaciones Pagina 10

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 48
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 9
10
3.4 Replacing rotating gobos
DANGER!
Replace gobos with the device switched off only.
Unplug from mains before!
1. Disconnect the xture from mains and allow it to cool.
2. Remove the bottom plastic cover of the head by loosening the 4 quarter-turn fasteners on the cover.
3. Gently pull up the gobo holder from the rotation gobo wheel
.
4. Carefully remove the gobo and the spring gobo-lock from the gobo holder by pushing to the gobe from the side
without toothed wheel
t. Do not touch the surface of the pattern of the glass gobo - use a suitable glove.
Be careful! Glass!
5. Insert the new gobo (glazy side towards the lamp). Insert the spring-gobo lock
to secure it in the gobo holder.
6. Insert the gobo holder back into rotating gobo wheel
.
5. Replace the bottom cover before applying power.
Vista de pagina 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 47 48

Comentarios a estos manuales

Sin comentarios